Sheath Introducer Kit

BT-SI-1
  • Used to guide the insertion of diagnostic or interventional devices into the human vascular system.
  • Wide variety of sets and sheaths in adult and pediatric sizes.
  • Smooth transition between sheath and dilator
  • Material includes:ETFE, PP.
  • Maximum flexibility without kinking or compression.
  • Taper tip design to reduce potential tissue trauma.
  • Lubricious sheath and dilator.
  • Radiopaque sheath with hemostasis valve and sideport with attached 3-way stopcock.
  • Different configurations and combinations are offered to meet your access needs.
  • Supplied sterile in tray or sterile pouch. Intended for one-time use.

 

Specification

A Kit:Contains sheath and dilator

Inner diameter *Guidewire compatibility *Sheath length
11cm 23cm
4Fr 0.035" BT-SI-1-04N110-35000-00 BT-SI-1-04N230-35000-00
5Fr 0.038" BT-SI-1-05N110-38000-00 BT-SI-1-05N230-38000-00
6Fr 0.038" BT-SI-1-06N110-38000-00 BT-SI-1-06N230-38000-00
7Fr 0.038" BT-SI-1-07N110-38000-00 BT-SI-1-07N230-38000-00
8Fr 0.038" BT-SI-1-08N110-38000-00  
9Fr 0.038" BT-SI-1-09N110-38000-00  

A Kit

B Kit:Contains sheath, dilator and *guidewire

Inner Diameter Order Number *Sheath length
11cm 23cm
4Fr 0.025" BT-SI-1-044110-25045-00 BT-SI-1-044230-25080-00
5Fr 0.035" BT-SI-1-054110-35045-00 BT-SI-1-054230-35080-00
6Fr 0.035" BT-SI-1-064110-35045-00 BT-SI-1-064230-35080-00
7Fr 0.035" BT-SI-1-074110-35045-00 BT-SI-1-074230-35080-00
8Fr 0.035" BT-SI-1-084110-35045-00  
9Fr 0.035" BT-SI-1-094110-35045-00  

B Kit

C Kit:Contains sheath, dilator ,*guidewire and *entry needle

Inner Diameter Order Number *Sheath length
11cm 23cm
4Fr 0.025" BT-SI-1-044110-25045-13 BT-SI-1-044230-25080-13
5Fr 0.035" BT-SI-1-054110-35045-11 BT-SI-1-054230-35080-11
6Fr 0.035" BT-SI-1-064110-35045-11 BT-SI-1-064230-35080-11
7Fr 0.035" BT-SI-1-074110-35045-11 BT-SI-1-074230-35080-11
8Fr 0.035" BT-SI-1-084110-35045-11  
9Fr 0.035" BT-SI-1-094110-35045-11  

C Kit

D Kit:Contains sheath, dilator and *guidewire,*entry needle and syringe

Inner Diameter Order Number *Sheath length
11cm 23cm
4Fr 0.025" BT-SI-1-044110-25045-33 BT-SI-1-044230-25080-33
5Fr 0.035" BT-SI-1-054110-35045-31 BT-SI-1-054230-35080-31
6Fr 0.035" BT-SI-1-064110-35045-31 BT-SI-1-064230-35080-31
7Fr 0.035" BT-SI-1-074110-35045-31 BT-SI-1-074230-35080-31
8Fr 0.035" BT-SI-1-084110-35045-31  
9Fr 0.035" BT-SI-1-094110-35045-31  

D Kit

E Kit:Contains sheath, dilator and *guidewire, *entry needle, syringe and scalpel

Inner Diameter Order Number *Sheath length
11cm 23cm
4Fr 0.025" BT-SI-1-044110-25045-13 BT-SI-1-044230-25080-13
5Fr 0.035" BT-SI-1-054110-35045-11 BT-SI-1-054230-35080-11
6Fr 0.035" BT-SI-1-064110-35045-11 BT-SI-1-064230-35080-11
7Fr 0.035" BT-SI-1-074110-35045-11 BT-SI-1-074230-35080-11
8Fr 0.035" BT-SI-1-084110-35045-11  
9Fr 0.035" BT-SI-1-094110-35045-11  

E Kit

*Guidewire compatibility: 0.018", 0.021", 0.025", 0.035" for 4Fr~6Fr; 0.025", 0.035", 0.038" for 5Fr~7Fr; 0.035",0.038" for 8Fr~9Fr.

*Sheath length: 5cm, 7cm,10cm,16cm,23cm, 25cm for 4Fr~7Fr;5cm, 7cm,10cm,11cm for 8Fr~9Fr.

*Guidewire: Stainless steel guidewire or Hydrophilic coated guidewire.

*Entry needle:Puncture needle or IV Catheter.

Remark: Items are not CE-marked.

Login for more information